Differential Pressure Transmitter with digital display

Differential Pressure Transmitter with digital display

Monitoring / controlling clean rooms, room pressure monitoring, ranges from 0-25 Pa to 0-60 bar, 2-, 3-wire units; standardized output signals (mA, VDC); for gases and liquids; piezo or Hall Sensor

Differential Pressure Transmitter with digital display
for air and non corrosive gases

TM 265

For air and non-corrosive gases, ranges from 0-100 Pa to 0-30 kPa, ranges selectable via Jumper, output signal: 0-10 VDC, colored display, fully programmable, connection: M12-plug

TMP-MSX

The Series TMP-MSX Differential Pressure Transmitter combines the stability and versatility of the original Series TMP-MS2 transmitter for use in building control applications. The TMP-MSX simplifies the ordering process to deliver the desired configuration, which reduces product setup time. Pressure ranges are available in Pa, mm w.c., and in w.c. All pressure ranges can be configured in unidirectional or bidirectional modes, providing a total of 32 ranges. The MSX transmitter can provide a linear pressure output or a linear velocity output with the square root extraction from the transmitter. Additional parameters have been included to expand the square root capability for calculating flow. Dual voltage and milliamp output signals can be used to provide both control and equipment output signal verification.

TMP-MSXP

The Series TMP-MSX Pro Differential Pressure Transmitter is the professional differential pressure transmitter meeting stringent industry standards with innovative global product design. The device has exceptional stability for use in critical building performance applications with the popular versatility of our original Series TMP-MS2 transmitter. The TMP-MSX Pro simplifies the ordering process to deliver the desired configuration, which reduces product setup time. Pressure ranges of Pa, mm w.c., and in w.c. are available per device. All pressure ranges can be configured in unidirectional or bidirectional modes providing a total of 32 ranges. The TMP-MSX Pro transmitter can provide a linear pressure output or a linear velocity output with the square root extraction from the transmitter. Additional parameters have been included to expand the square root capability to calculate flow. Dual voltage and milliamp output signals can be used to provide control and equipment output signal verification.

TMP-MS2

Magnesense, for air and non-corrosive gases, ranges from 0-25 Pa to 0-100 Pa and 0-200 Pa to 0-1250 Pa, field selectable, 4-20 mA or 0-10 VDC output signal, high accuracy through Hall sensor, digital push buttons for zero and span, factory default could easily restore, various kinds of mounting, optional Modbus or BacNet version

TMK-984

For air and non-corrosive gases, ranges from 0-100 Pa to 0-250 kPa, output signals 0-10 VDC or 4-20 mA, 2- or 3-wire units, power supply: 24 VAC/DC or 24 VDC, for wall mounting with LED display

TMK-984A

For air and non-corrosive gases, ranges from 0-25 Pa to 0-250 kPa, self - zeroing, output signals 0-10 VDC or 4-20 mA, 2- or 3-wire units, power supply: 24 VAC/DC or 24 VDC, for wall mounting

TMK-984Q

For air and non-corrosive gases, 8 ranges in one unit, from 50-0-50 Pa to 0-1000 Pa, self - zeroing, output signals 0-10 VDC or 4-20 mA, 2- or 3-wire units, power supply: 24 VAC/DC or 24 VDC, for wall mounting

TMP-DM2000

The TMP-DM-2000 differential pressure transmitter senses the pressure of air and compatible gases and sends a standard 4-20 mA output signal. The housing is specifically designed to mount in the same diameter cutout as a standard Magnehelic gage. Digital push-button zero and span simplify calibration over typical turn-potentiometers. An optional 3.5-digit LCD shows process and engineering units.

TM 169

For air and non-corrosive gases, ABS plastic enclosure, ranges from 0-100 Pa to 0-250 kPa, output signals: 0-10 VDC or 4-20 mA, 2- or 3-wire units, power supply: VAC/DC or 24 VDC, for wall mounting, option: LED display, additional set point (NPN), selectable range

TM 169A

For air and non-corrosive gases, ABS plastic enclosure, ranges from 0-25 Pa to 0-250 kPa, self-zeroing, output signals: 0-10 VDC or 4-20 mA, 2- or 3-wire units, power supply: VAC/DC or 24 VDC, for wall mounting, option: LED display, option: additional set point (NPN)

TM 169-MOD

The transmitters TM 169-MOD are used to measure differential pressure, volume flow or flow velocity and pressure. The measured value can be output and the parameterization on the device can be done via the Modbus RTU data interface.

The response time of the output signal can be variably set via Modbus.
For TM 169-Mod and TM 169-Mod-VM press the MODE/Offset button or set via Modbus in an unpressurized state to adjust the offset to zero. The Versions TM 169A-Mod and TM 169-VA-Modbus perform an automated zero offset compensation. A red LED display shows the pressure value, volume flow or flow velocity.
Can be mounted in any position. The zero offset calibration eliminates any possible position error.

TM-PEL

TM-PEL - differential pressure transmitters are made for clean / isolation room applications. The zero point of the transmitter remains exact by means of the automatic zeroing, eliminating regularly possible zero point drifting.

TM-PEL-1000

TM-PEL 1000 differential pressure transmitters are made for controlling fans and monitoring filters of the air handling units (AHU). Model PEL 1000-N has a built-in digital display with the resolution of 1Pa.

TM-PEL-2500

TM-PEL 2500 is a pressure transmitter detecting pressures and pressure differences of the air-handling system. Pressure- or flow linear output can be selected at the commissioning. Excellent accuracy of the measurement is guaranteed by the automatic zero point calibration. The proper range of measuring can be chosen at commissioning from eight different ranges

TM-PEL-8K

TM-PEL 8K is a pressure transmitter detecting pressures and pressure differences of the air-handling system. Excellent accuracy of the measurement is guaranteed by the automatic zero point calibration. The proper range of measuring can be chosen at commissioning from eight different ranges, Option: Modbus RTU

TM-KPEL-M-N

KPEL-M is a pressure transmitter for detecting pressures and pressure differences of the air-handling system. The device can be connected to any system that supports Modbus RTU protocol. The transmitter has two separate temperature compensated pressure measurements. The pressure range can be selected separately for both measurements. The transmitter can also be used as a controller. The controller settings can be changed by using the ML-SER tool or via Modbus. The transmitter outputs can also be changed to inputs which can be read via Modbus. The inputs can be selected to be 0?10 V, digital or temperature inputs. The supported temperature elements are NTC 10, NTC 20, Pt1000, Ni1000 and Ni1000-LG.

Room Monitoring

TMP-RPMC

The Series TMP-RPMC StabiliSENSE™ Critical Room Pressure Monitor is designed for critical low differential pressure applications that require stringent pressure monitoring and alarming. The Series TMP-RPMC can be configured to monitor positive or negative pressure in protected environments and clean manufacturing areas. The TMP-RPMC is a complete system which enables access to pressure, security, calibration, and alarm setup. The TMP-RPMC StabiliSENSE™ critical room pressure monitor has a brushed stainless steel bezel that allows for easy cleaning.

The TMP-RPMC StabiliSENSE™ critical room pressure monitor has built-in status indication LEDs that will appear green when within the user-defined pressure set range and will appear orange when outside of the pressure set range. 2 SPDT independent control relays with adjustable deadbands are also provided along with a 4-20 mA process output.

TMP-RPME

The Series TMP-RPME FlexiSENSE™ Room Pressure Monitor is designed for low differential pressure applications that require stringent pressure monitoring and alarming. The Series TMP-RPME FlexiSENSE™ room pressure monitor can be configured to monitor positive or negative pressure in protected environments and clean manufacturing areas. The TMP-RPME FlexiSENSE™ room pressure monitor is a complete system with a fixed segment LCD which enables access to pressure, security, calibration, and alarm setup. The TMP-RPME has a brushed stainless steel bezel that allows for easy cleaning.

The TMP-RPME FlexiSENSE™ room pressure monitor has built-in status indication LEDs that will appear green when within the user-defined pressure set range and will appear orange when outside of the pressure set range. 2 SPDT independent control relays with adjustable deadbands are also provided along with a 4-20 mA process output.