Differential Pressure Gages

TMP-2000-HA

The TM-MIC-U1000HM is an ultrasonic clamp-on heat/energy meter that uses ultrasound to measure flow rate and PT100 temperature sensors to measure flow and return temperatures. The TM-MIC-U1000HM displays energy rate and totalised energy with pulse output and Modbus communication, so it can be used as a standalone meter or as an integral part of an aM&T or BEM?s system. Simple to install ? clamp-on to the pipe, set the pipe diameter and connect the power, no specialist skills or tools required and Modbus compatible.

Controllers, Room units and universal controllers

TM-Overview

Produal controllers are widely used in various commercial and public facilities to implement optimal room climate control. The best possible indoor environment is offered for hotel guests, office staff, audience members or patients by ensuring versatile and precise detection and on-demand control

TM-ROU

TM-ROU is an advanced room unit designed to be used with the middle roof control units. The basic room unit includes temperature measurement. Other measurements like CO2 or PIR can be bought as options.
NOTE: ROU works as a master in Modbus network.

TM-C230

TM-C230 is a versatile control unit specifically designed for individual room temperature, fan coils, VAV and zone control applications. The control unit can be connected to systems that support Modbus RTU protocol (RS-485).

The control unit settings and output functions can be changed by using the buttons and display on room unit TM-E202 or a configuration unit TM-H203. The controller has two programmable 230 Vac, two 0…10 Vdc outputs and three relays for fan speed control or damper actuators.

TM-C222

TM-C222 is a versatile control unit specifically designed for individual room temperature, VAV and zone control applications. The control unit can be connected to any system that supports Modbus RTU protocol by using the RS-485 connection.
The control unit settings and output functions can be changed by using the buttons and display on room unit TM-E201/E202 or a configuration unit TM-H203. The controller has two programmable 24 Vac, two 0…10 Vdc outputs and a control port for relay TM-RL203.

Air Flow Indicator

TMF-DAFA

The Series TMF-DAFA Air Flow Indicator and Alarm alerts users of low or no air flow conditions in pipes utilizing a thin, field trimmable vane to sense the air flow rate. An 85 dB audible buzzer alternates with a bright red LED to alert users when the air flow rate drops, indicating low or no flow in the pipe. The TMF-DAFA is battery powered to provide versatility for where it can be installed, and offers a yellow LED to indicate a low battery. This device is ideal for monitoring radon mitigation systems by detecting a loss of air flow in the pipe and providing a signal to homeowners if the fan has stopped operating.



Wireless Sensors

TM-RYFL-XS

The TM-RYFL-XS is a wireless I/O module which can be used to transfer measurements and control information. Communicating between the control system and I/O module is done through TM-FLTA base station Modbus connection. Two input signals can be forwarded and one relay output with changeover contacts can be controlled.



Electromagnetic Flow Transmitter

TM-IEF

The SERIES TMF-IEF Insertion Electromagnetic Flow Transmitter is an adjustable insertion flowmeter featuring electromagnetic technology that accurately and reliably measures fluid velocity in addition to providing several continuous signal outputs. This series is specifically designed to offer superior performance paired with simple installation and use. One unit is adjustable to fit pipe sizes from 4 to 36“ (101.6 to 914.4 mm), and offers several output options including selectable BACnet MS/TP or Modbus® RTU communications protocol over 2-wire RS-485 in addition to the standard analog, frequency and alarm outputs.